im1 im4 im3
 
Aerovent Australia -  Premier Fan Engineering and Manufacture Premier Fan Engineering
& Manufacture

Login

Model Number  


Amber Series

Plate Mounted Axial Ex'd'

Model: AMP045-1


Plate Mounted Axial Ex'd'

Common Applications
The Amber Series of pre-engineered plate mounted fans incorporate a flameproof motor and anti-static blades. Typical applications include battery room exhaust and spray booths. Finger guards are fitted to the fan inlet as standard.

Electrical
Available in 240V single-phase only. Motors are not speed controllable.

Materials
Galvanised steel construction with anti-static impeller
High efficiency anti-static axial impeller.

Warning
Warranty may be void if wiring and installation guidelines are not followed.


Performance Standard ANSI / AMCA 210-99


Downloads


Wiring
Diagram

Installation
& Maintenance
Instructions


 

Save as PDF
Project:
 
Fan Ref:
 


Performance Data


Model Specifications

Power,
kW
Current,
Amps
Speed,
rpm
Power
Supply
dBA @
3m
Mass,
kg
0.553.71420240V / 1ph / 50Hz5358


Sound Power Level (dB re10-12 W) at Octave Band Mid-Frequency (Hz)

631252505001k2k4k8k
7471696867676863


Dimensions, mm
Plate Mounted Axial Ex'd'

ABCDEFG
4523755765351001411
Due to Aerovent Australia’s constant product improvement and development program, product details may change without prior notice.

Copyright © 2019 Aerovent Australia. All rights reserved.
 
im6 im8 im7